Single beam signals were in the order of 10–30 V After balancing

Single beam signals were in the order of 10–30 V. After balancing the two signals, the BIBW2992 difference signal could be strongly amplified without risk of amplifier saturation. The amplitude of the single signals (corresponding to I), which may be more than 1,000× larger than the recorded signal changes (corresponding to ΔI), were determined with the help of a special calibration routine, involving a defined transient decrease AZD5363 purchase of the 520 nm signal with respect to the 550 nm signal (via corresponding decrease in LED current). The original difference signals were measured in Volt units, which were transformed into ΔI/I units by the calibration. The long-term stability

of the dual-beam difference signal was tested with the help of an “artificial leaf” consisting of a plastic filter sheet with a transmittance spectrum in the green region similar to that of a green leaf (Roscolux #01, Light Amber Bastard). Signal stability was best at relatively low frequency of the

pulse-modulated ML (less than 10−4 ΔI/I units drift over a 5-min time period at frequencies up to 1 kHz). On the other hand, for measurements of flash-induced rapid changes maximal pulse modulation frequency of 200 kHz was used, where the signal/noise is optimal and the drift (approximately 2 × 10−3 ΔI/I units drift over a 5-min time period) does not affect measurements in the s time range. Maximal pulse modulation www.selleckchem.com/products/BafilomycinA1.html frequency of 200 kHz was also applied for the flux measurements described under “Results and discussion” section, where not only the ML, but also the AL is modulated. Results and discussion Partitioning of total pmf between ΔpH and ΔΨ in tobacco leaves Analysis of DIRK method has been advanced by Kramer and co-workers for non-intrusive measurement

of the rate of electron flow via P700 (Sacksteder and Kramer 2000), for assessment of the ΔpH and ΔΨ components of overall pmf (Cruz et al. 2001; Avenson et al. 2004a) and for determination of the rate of proton efflux via the ATP-synthase (Sacksteder et al. 2000; Kanazawa and Kramer 2002; Kramer et al. 2003; Cruz et al. 2005). Most of this previous Sitaxentan work has been based on single beam absorbance measurements of the ECS around 515–520 nm. In order to minimize problems arising from overlapping “light scattering” changes (peaking at 535 nm) a diffused-optics spectrophotometer (Kramer and Sacksteder 1998) or non-focusing optics spectrophotometer (Sacksteder et al. 2001) were used. In our P515 measuring system “light scattering” changes are largely eliminated by the dual-wavelength (550–520 nm) approach (Schreiber and Klughammer 2008, see also corresponding section under “Materials and methods” section). While the dual-wavelength technique does not eliminate changes due to zeaxanthin (peaking around 505 nm), such changes are unlikely to contribute to dark-induced relaxation kinetics, as they are very slow and, hence, can be readily distinguished from the much more rapid ECS changes analyzed by the DIRK method.

Comments are closed.